Dog F8 (Coagulation Factor VIII) ELISA Kit
€0.00
In stock
SKU
ELK6034
Catalog Number: ELK6034
Reactivity: Dog
Standard Range: 78.13-5000 pg/mL
Sensitivity: 28 pg/mL
Information
Request Manual
Questions? Contact us!
Reactivity: Dog
Standard Range: 78.13-5000 pg/mL
Sensitivity: 28 pg/mL
Information
Request Manual
Questions? Contact us!
Test Principle:
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Coagulation Factor VIII(F8). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Coagulation Factor VIII(F8). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Coagulation Factor VIII(F8), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Coagulation Factor VIII(F8) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Metabolic pathway, Hematology
Alternative Names:
FVIII, AHF, HEMA, F8B, F8C, Antihemophilic Globulin, Hemophilia A, Anti-Hemophilic Factor A, FVIII Procoagulant Component, F8 Protein
Sample Type:
plasma
Assay Type: Sandwich
Standard: 5000 pg/mL
Assay Length: 4.5h
Assay Length: For Research Use Only
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Coagulation Factor VIII(F8). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Coagulation Factor VIII(F8). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Coagulation Factor VIII(F8), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Coagulation Factor VIII(F8) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Metabolic pathway, Hematology
Alternative Names:
FVIII, AHF, HEMA, F8B, F8C, Antihemophilic Globulin, Hemophilia A, Anti-Hemophilic Factor A, FVIII Procoagulant Component, F8 Protein
Sample Type:
plasma
Assay Type: Sandwich
Standard: 5000 pg/mL
Assay Length: 4.5h
Assay Length: For Research Use Only
| Is Featured? | No |
|---|
Write Your Own Review