Eotaxin-2 monoclonal, anti-human
€0.00
In stock
SKU
AC-ABG10091
Catalog Number: AC-ABG10091
Size(s): 500 µg
Host: Mouse
Applications: WB, IHC, E
Datasheet
Request Information
Size(s): 500 µg
Host: Mouse
Applications: WB, IHC, E
Datasheet
Request Information
Source:
Produced in BALB/c mice using highly pure (>98%) recombinant human Eotaxin-2 as the immunizing antigen. This IgG1k antibody was purified from ascites fluid by antigen affinity chromatography.
Western Blot:
To detect hEotaxin-2 by Western Blot analysis this antibody can be used at a concentration of 0.25-0.50 μg/ml. Used in conjunction with compatible secondary reagents the detection limit for recombinant hEotaxin-2 is 0.5-1.0 ng/lane, under non-reducing conditions.
Sandwich ELISA:
In a sandwich ELISA (assuming 100 μl/well), a concentration of 2.0-4.0 μg/ml of this antibody will detect at least 80.0 pg/well of recombinant human Eotaxin-2 when used with BioGems biotinylated antigen affinity purified anti-human Eotaxin-2 (60-123BT) as the detection antibody at a concentration of approximately 1.0-2.0 μg/ml.
Immunohistochemistry:
This antibody stained formalin-fixed, paraffin-embedded sections of human tonsil. The recommended concentration is 10.0 μg/ml with an overnight incubation at 4˚C. An HRP-labeled polymer detection system was used with a DAB chromogen. Heat induced antigen retrieval with a pH 8.0 EDTA buffer is recommended. Optimal concentrations and conditions may vary. Protocol and staining provided by Dr. Lauren Binge, Laboratory of Prof. Charles Mackay, Monash Univeristy, Australia.
Formulation: A sterile filtered antibody solution was lyophilized from PBS.
Reconstitution: Centrifuge vial prior to opening. Reconstitute in sterile water to a concentration of 0.1-1.0 mg/ml.
Produced in BALB/c mice using highly pure (>98%) recombinant human Eotaxin-2 as the immunizing antigen. This IgG1k antibody was purified from ascites fluid by antigen affinity chromatography.
Western Blot:
To detect hEotaxin-2 by Western Blot analysis this antibody can be used at a concentration of 0.25-0.50 μg/ml. Used in conjunction with compatible secondary reagents the detection limit for recombinant hEotaxin-2 is 0.5-1.0 ng/lane, under non-reducing conditions.
Sandwich ELISA:
In a sandwich ELISA (assuming 100 μl/well), a concentration of 2.0-4.0 μg/ml of this antibody will detect at least 80.0 pg/well of recombinant human Eotaxin-2 when used with BioGems biotinylated antigen affinity purified anti-human Eotaxin-2 (60-123BT) as the detection antibody at a concentration of approximately 1.0-2.0 μg/ml.
Immunohistochemistry:
This antibody stained formalin-fixed, paraffin-embedded sections of human tonsil. The recommended concentration is 10.0 μg/ml with an overnight incubation at 4˚C. An HRP-labeled polymer detection system was used with a DAB chromogen. Heat induced antigen retrieval with a pH 8.0 EDTA buffer is recommended. Optimal concentrations and conditions may vary. Protocol and staining provided by Dr. Lauren Binge, Laboratory of Prof. Charles Mackay, Monash Univeristy, Australia.
Formulation: A sterile filtered antibody solution was lyophilized from PBS.
Reconstitution: Centrifuge vial prior to opening. Reconstitute in sterile water to a concentration of 0.1-1.0 mg/ml.
| Is Featured? | No |
|---|
Write Your Own Review