General ALCAR (Acetylcarnitine) ELISA Kit
€0.00
In stock
SKU
ELK8184
Catalog Number: ELK8184
Reactivity: General
Standard Range: 78.13-5000 ng/mL
Sensitivity: 25.2 ng/mL
Information
Request Manual
Questions? Contact us!
Reactivity: General
Standard Range: 78.13-5000 ng/mL
Sensitivity: 25.2 ng/mL
Information
Request Manual
Questions? Contact us!
Test Principle:
This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Acetylcarnitine(ALCAR) protein. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Acetylcarnitine(ALCAR). Next,Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Acetylcarnitine(ALCAR) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Metabolic pathway, Neuro science, Nutrition metabolism,
Alternative Names:
Acetyl-L-carnitine
Sample Type:
serum, plasma and other biological fluids
Assay Type: Competitive Inhibition
Standard: 5000 ng/mL
Assay Length: 2h
Assay Length: For Research Use Only
This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Acetylcarnitine(ALCAR) protein. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Acetylcarnitine(ALCAR). Next,Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Acetylcarnitine(ALCAR) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Metabolic pathway, Neuro science, Nutrition metabolism,
Alternative Names:
Acetyl-L-carnitine
Sample Type:
serum, plasma and other biological fluids
Assay Type: Competitive Inhibition
Standard: 5000 ng/mL
Assay Length: 2h
Assay Length: For Research Use Only
| Is Featured? | No |
|---|