Test Principle:
This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Homovanillic Acid(HVA) protein. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Homovanillic Acid(HVA). Next,Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Homovanillic Acid(HVA) in the samples is then determined by comparing the OD of the samples to the standard curve.
Alternative Names:
HOC6H3(OCH3)CH2COOH, 3-Methoxy-4-hydroxyphenyl Acetic Acid, 4-Hydroxy-3-Methoxy-Benzeneacetic Acid, 4-Hydroxy-3-Methoxyphenylacetic Acid
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Type: Competitive Inhibition
Standard: 200 ng/mL
Assay Length: 2h
Assay Length: For Research Use Only
This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Homovanillic Acid(HVA) protein. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Homovanillic Acid(HVA). Next,Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Homovanillic Acid(HVA) in the samples is then determined by comparing the OD of the samples to the standard curve.
Alternative Names:
HOC6H3(OCH3)CH2COOH, 3-Methoxy-4-hydroxyphenyl Acetic Acid, 4-Hydroxy-3-Methoxy-Benzeneacetic Acid, 4-Hydroxy-3-Methoxyphenylacetic Acid
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Type: Competitive Inhibition
Standard: 200 ng/mL
Assay Length: 2h
Assay Length: For Research Use Only