General rT3 (Reverse Triiodothyronine) ELISA Kit
€0.00
In stock
SKU
ELK7898
Catalog Number: ELK7898
Reactivity: General
Standard Range: 93.75-6000 pg/mL
Sensitivity: 27.55 pg/mL
Information
Request Manual
Questions? Contact us!
Reactivity: General
Standard Range: 93.75-6000 pg/mL
Sensitivity: 27.55 pg/mL
Information
Request Manual
Questions? Contact us!
Test Principle:
This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Reverse Triiodothyronine(rT3) protein. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Reverse Triiodothyronine(rT3). Next,Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Reverse Triiodothyronine(rT3) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Infection immunity, Endocrinology, Hormone metabolism, Autoimmunity
Alternative Names:
RT3, r-T3, Reverse T3, (2S)-2-Amino-3-[4-(4-Hydroxy-3,5-Diiodophenoxy)-3-Iodophenyl]propanoic Acid, 3,3',5'-Triiodo-L-thyronine
Sample Type:
serum, plasma and other biological fluids
Assay Type: Competitive Inhibition
Standard: 6000 pg/mL
Assay Length: 2h
Assay Length: For Research Use Only
This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Reverse Triiodothyronine(rT3) protein. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Reverse Triiodothyronine(rT3). Next,Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Reverse Triiodothyronine(rT3) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Infection immunity, Endocrinology, Hormone metabolism, Autoimmunity
Alternative Names:
RT3, r-T3, Reverse T3, (2S)-2-Amino-3-[4-(4-Hydroxy-3,5-Diiodophenoxy)-3-Iodophenyl]propanoic Acid, 3,3',5'-Triiodo-L-thyronine
Sample Type:
serum, plasma and other biological fluids
Assay Type: Competitive Inhibition
Standard: 6000 pg/mL
Assay Length: 2h
Assay Length: For Research Use Only
| Is Featured? | No |
|---|
Write Your Own Review