Test Principle:
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to ADO(Adenosine). Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to ADO(Adenosine). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain ADO(Adenosine), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of ADO(Adenosine) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Biochemistry
Alternative Names:
Adenosine
Sample Type:
Serum, plasma, tissue homogenates and other biological fluids.
Assay Type: Sandwich
Standard: 100 ng/mL
Assay Length: 3.5h
Assay Length: For Research Use Only
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to ADO(Adenosine). Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to ADO(Adenosine). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain ADO(Adenosine), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of ADO(Adenosine) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Biochemistry
Alternative Names:
Adenosine
Sample Type:
Serum, plasma, tissue homogenates and other biological fluids.
Assay Type: Sandwich
Standard: 100 ng/mL
Assay Length: 3.5h
Assay Length: For Research Use Only
| Is Featured? | No |
|---|
Write Your Own Review