Human Anti-IgA (Anti-Immunoglobulin A Antibody) ELISA Kit
€0.00
In stock
SKU
ELK8046
Catalog Number: ELK8046
Reactivity: Human
Standard Range: 6.25-400 ng/mL
Sensitivity: 2.36 ng/mL
Information
Request Manual
Questions? Contact us!
Reactivity: Human
Standard Range: 6.25-400 ng/mL
Sensitivity: 2.36 ng/mL
Information
Request Manual
Questions? Contact us!
Test Principle:
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with Anti-Immunoglobulin A(Anti-IgA) protein. Standards or samples are then added to the appropriate microtiter plate wells with Anti-Immunoglobulin A(Anti-IgA) protein. Then add a biotin-conjugated Anti-Immunoglobulin A(Anti-IgA) protein. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Anti-Immunoglobulin A Antibody(Anti-IgA) , biotin-conjugated protein and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Anti-Immunoglobulin A Antibody(Anti-IgA) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Infection immunity, Immune molecule, Hematology, Pulmonology
Sample Type:
serum, plasma and other biological fluids
Assay Type: Sandwich
Standard: 400 ng/mL
Assay Length: 4.5h
Assay Length: For Research Use Only
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with Anti-Immunoglobulin A(Anti-IgA) protein. Standards or samples are then added to the appropriate microtiter plate wells with Anti-Immunoglobulin A(Anti-IgA) protein. Then add a biotin-conjugated Anti-Immunoglobulin A(Anti-IgA) protein. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Anti-Immunoglobulin A Antibody(Anti-IgA) , biotin-conjugated protein and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Anti-Immunoglobulin A Antibody(Anti-IgA) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Infection immunity, Immune molecule, Hematology, Pulmonology
Sample Type:
serum, plasma and other biological fluids
Assay Type: Sandwich
Standard: 400 ng/mL
Assay Length: 4.5h
Assay Length: For Research Use Only
| Is Featured? | No |
|---|
Write Your Own Review