Human BTLA (B- and T-lymphocyte attenuator) ELISA Kit
€0.00
In stock
SKU
ELK8669
Catalog Number: ELK8669
Reactivity: Human
Standard Range: 0.47-30 ng/mL
Sensitivity: 0.22 ng/mL
Information
Request Manual
Questions? Contact us!
Reactivity: Human
Standard Range: 0.47-30 ng/mL
Sensitivity: 0.22 ng/mL
Information
Request Manual
Questions? Contact us!
Test Principle:
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to B- and T-lymphocyte attenuator(BTLA). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to B- and T-lymphocyte attenuator(BTLA). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain B- and T-lymphocyte attenuator(BTLA), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of B- and T-lymphocyte attenuator(BTLA) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Cardiac function, Cancer
Alternative Names:
B and T lymphocyte associated protein, B and T lymphocyte attenuator, B and T lymphocyte associated, B- and T-lymphocyte attenuator, B- and T-lymphocyte-associated protein, BTLA, BTLA_HUMAN, BTLA1, CD272, CD272 antigen, FLJ16065, MGC129743
Sample Type:
Serum, plasma, urine, tissue homogenates, cell culture supernates and other biological fluids
Assay Type: Sandwich
Standard: 30 ng/mL
Assay Length: 4.5h
Assay Length: For Research Use Only
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to B- and T-lymphocyte attenuator(BTLA). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to B- and T-lymphocyte attenuator(BTLA). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain B- and T-lymphocyte attenuator(BTLA), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of B- and T-lymphocyte attenuator(BTLA) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Cardiac function, Cancer
Alternative Names:
B and T lymphocyte associated protein, B and T lymphocyte attenuator, B and T lymphocyte associated, B- and T-lymphocyte attenuator, B- and T-lymphocyte-associated protein, BTLA, BTLA_HUMAN, BTLA1, CD272, CD272 antigen, FLJ16065, MGC129743
Sample Type:
Serum, plasma, urine, tissue homogenates, cell culture supernates and other biological fluids
Assay Type: Sandwich
Standard: 30 ng/mL
Assay Length: 4.5h
Assay Length: For Research Use Only
| Is Featured? | No |
|---|
Write Your Own Review