Test Principle:
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to 7-Dehydrocholesterol Reductase(DHCR7). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to 7-Dehydrocholesterol Reductase(DHCR7). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain 7-Dehydrocholesterol Reductase(DHCR7), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of 7-Dehydrocholesterol Reductase(DHCR7) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Enzyme & Kinase
Alternative Names:
DHCR-7, SLOS, D7SR, Smith-Lemli-Opitz Syndrome, Putative sterol reductase SR-2, Sterol Delta(7)-reductase
Sample Type:
Tissue homogenates and other biological fluids.
Assay Type: Sandwich
Standard: 10 ng/mL
Assay Length: 4.5h
Assay Length: For Research Use Only
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to 7-Dehydrocholesterol Reductase(DHCR7). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to 7-Dehydrocholesterol Reductase(DHCR7). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain 7-Dehydrocholesterol Reductase(DHCR7), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of 7-Dehydrocholesterol Reductase(DHCR7) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Enzyme & Kinase
Alternative Names:
DHCR-7, SLOS, D7SR, Smith-Lemli-Opitz Syndrome, Putative sterol reductase SR-2, Sterol Delta(7)-reductase
Sample Type:
Tissue homogenates and other biological fluids.
Assay Type: Sandwich
Standard: 10 ng/mL
Assay Length: 4.5h
Assay Length: For Research Use Only
| Is Featured? | No |
|---|
Write Your Own Review