Human IgG1 (Immunoglobulin G1) ELISA Kit
€0.00
In stock
SKU
ELK5154
Catalog Number: ELK5154
Reactivity: Human
Standard Range: 6.25-400 ug/mL
Sensitivity: 2.71 ug/mL
Information
Request Manual
Questions? Contact us!
Reactivity: Human
Standard Range: 6.25-400 ug/mL
Sensitivity: 2.71 ug/mL
Information
Request Manual
Questions? Contact us!
Test Principle:
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Immunoglobulin G1(IgG1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Immunoglobulin G1(IgG1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Immunoglobulin G1(IgG1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Immunoglobulin G1(IgG1) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Immune molecule
Alternative Names:
IGHG1, Ig Gamma-1 Chain C Region, Immunoglobulin Heavy Constant Gamma 1, G1m Marker, Immunoglobulin Gm1
Sample Type:
serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Type: Sandwich
Standard: 400 ug/mL
Assay Length: 4.5h
Assay Length: For Research Use Only
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Immunoglobulin G1(IgG1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Immunoglobulin G1(IgG1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Immunoglobulin G1(IgG1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Immunoglobulin G1(IgG1) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Immune molecule
Alternative Names:
IGHG1, Ig Gamma-1 Chain C Region, Immunoglobulin Heavy Constant Gamma 1, G1m Marker, Immunoglobulin Gm1
Sample Type:
serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Type: Sandwich
Standard: 400 ug/mL
Assay Length: 4.5h
Assay Length: For Research Use Only
| Is Featured? | No |
|---|