Human LACRT (Lacritin) ELISA Kit
€0.00
In stock
SKU
ELK2907
Catalog Number: ELK2907
Reactivity: Human
Standard Range: 1.57-100 ng/mL
Sensitivity: 0.63 ng/mL
Information
Request Manual
Questions? Contact us!
Reactivity: Human
Standard Range: 1.57-100 ng/mL
Sensitivity: 0.63 ng/mL
Information
Request Manual
Questions? Contact us!
Test Principle:
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Lacritin(LACRT). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Lacritin(LACRT). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Lacritin(LACRT), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Lacritin(LACRT) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Immune molecule
Alternative Names:
Extracellular glycoprotein lacritin
Sample Type:
saliva, tears and other biological fluids
Assay Type: Sandwich
Standard: 100 ng/mL
Assay Length: 4.5h
Assay Length: For Research Use Only
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Lacritin(LACRT). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Lacritin(LACRT). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Lacritin(LACRT), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Lacritin(LACRT) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Immune molecule
Alternative Names:
Extracellular glycoprotein lacritin
Sample Type:
saliva, tears and other biological fluids
Assay Type: Sandwich
Standard: 100 ng/mL
Assay Length: 4.5h
Assay Length: For Research Use Only
| Is Featured? | No |
|---|
Write Your Own Review