Human MCP (Membrane Cofactor Protein) ELISA Kit
€0.00
In stock
SKU
ELK1836
Catalog Number: ELK1836
Reactivity: Human
Standard Range: 12.5-800 pg/mL
Sensitivity: 4.8 pg/mL
Information
Request Manual
Questions? Contact us!
Reactivity: Human
Standard Range: 12.5-800 pg/mL
Sensitivity: 4.8 pg/mL
Information
Request Manual
Questions? Contact us!
Test Principle:
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Membrane Cofactor Protein(MCP). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Membrane Cofactor Protein(MCP). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Membrane Cofactor Protein(MCP), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Membrane Cofactor Protein(MCP) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: CD & Adhesion molecule
Alternative Names:
CD46, MIC10, TLX, TRA2, Trophoblast leukocyte common antigen, CD46 Molecule,Complement Regulatory Protein, CD46 Molecule,Complement Regulatory protein
Sample Type:
Serum, plasma, urine, saliva and other biological fluids
Assay Type: Sandwich
Standard: 800 pg/mL
Assay Length: 4.5h
Assay Length: For Research Use Only
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Membrane Cofactor Protein(MCP). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Membrane Cofactor Protein(MCP). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Membrane Cofactor Protein(MCP), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Membrane Cofactor Protein(MCP) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: CD & Adhesion molecule
Alternative Names:
CD46, MIC10, TLX, TRA2, Trophoblast leukocyte common antigen, CD46 Molecule,Complement Regulatory Protein, CD46 Molecule,Complement Regulatory protein
Sample Type:
Serum, plasma, urine, saliva and other biological fluids
Assay Type: Sandwich
Standard: 800 pg/mL
Assay Length: 4.5h
Assay Length: For Research Use Only
| Is Featured? | No |
|---|
Write Your Own Review