Catalog Number: ELK2664
Reactivity: Human
Standard Range: 31.25-2000 pg/mL
Sensitivity: 8.94 pg/mL
Information
Request Manual
Questions? Contact us!
Reactivity: Human
Standard Range: 31.25-2000 pg/mL
Sensitivity: 8.94 pg/mL
Information
Request Manual
Questions? Contact us!
Test Principle:
This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Proislet Amyloid Polypeptide(ProIAPP) protein. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Proislet Amyloid Polypeptide(ProIAPP). Next,Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Proislet Amyloid Polypeptide(ProIAPP) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Apoptosis, Infection immunity, Hepatology, Gastroenterology
Alternative Names:
Pro-IAPP, Pro-Amylin, Pro-Islet Amyloid Polypeptide
Sample Type:
Serum, plasma and other biological fluids
Assay Type: Competitive Inhibition
Standard: 2000 pg/mL
Assay Length: 2h
Assay Length: For Research Use Only
This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Proislet Amyloid Polypeptide(ProIAPP) protein. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Proislet Amyloid Polypeptide(ProIAPP). Next,Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Proislet Amyloid Polypeptide(ProIAPP) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Apoptosis, Infection immunity, Hepatology, Gastroenterology
Alternative Names:
Pro-IAPP, Pro-Amylin, Pro-Islet Amyloid Polypeptide
Sample Type:
Serum, plasma and other biological fluids
Assay Type: Competitive Inhibition
Standard: 2000 pg/mL
Assay Length: 2h