MCP-1 polyclonal biotin, anti-human
€0.00
In stock
SKU
AC-ABG10354
Catalog Number: AC-ABG10354
Size(s): 25 µg, 50 µg
Host: Rabbit
Applications: WB, E
Datasheet
Request Information
Size(s): 25 µg, 50 µg
Host: Rabbit
Applications: WB, E
Datasheet
Request Information
Source:
Produced from sera of rabbits pre-immunized with highly pure (>98%) recombinant hMCP-1/MCAF. Anti-Human MCP-1/MCAF specific antibody was purified by affinity chromatography and then biotinylated.
Western Blot:
To detect hMCP-1/MCAF by Western Blot analysis this antibody can be used at a concentration of 0.1 - 0.2 μg/ml. Used in conjunction with compatible secondary reagents the detection limit for recombinant hMCP-1/MCAF is 1.5 - 3.0 ng/lane, under either reducing or non-reducing conditions.
Sandwich ELISA:
To detect hMCP-1/MCAF by sandwich ELISA (using 100 μl/well antibody solution) a concentration of 0.25 / 1.0 μg/ml of this antibody is required. This biotinylated polyclonal antibody, in conjunction with BioGems Polyclonal Anti-Human MCP-1/MCAF (60-212P) as a capture antibody, allows the detection of at least 0.2 - 0.4 ng/well of recombinant hMCP-1/MCAF.
Direct ELISA:
To detect hMCP-1/MCAF by direct ELISA (using 100 μl/well antibody solution) a concentration of 0.25 / 1.0 μg/ml of this antibody is required. This biotinylated polyclonal antibody, in conjunction with compatible secondary reagents, allows the detection of at least 0.2 - 0.4 ng/well of recombinant hMCP-1/MCAF.
Formulation: A sterile filtered antibody solution was lyophilized from PBS, pH 7.2.
Reconstitution: Centrifuge vial prior to opening. Reconstitute in sterile PBS containing 0.1% BSA to a concentration of 0.1-1.0 mg/ml.
Produced from sera of rabbits pre-immunized with highly pure (>98%) recombinant hMCP-1/MCAF. Anti-Human MCP-1/MCAF specific antibody was purified by affinity chromatography and then biotinylated.
Western Blot:
To detect hMCP-1/MCAF by Western Blot analysis this antibody can be used at a concentration of 0.1 - 0.2 μg/ml. Used in conjunction with compatible secondary reagents the detection limit for recombinant hMCP-1/MCAF is 1.5 - 3.0 ng/lane, under either reducing or non-reducing conditions.
Sandwich ELISA:
To detect hMCP-1/MCAF by sandwich ELISA (using 100 μl/well antibody solution) a concentration of 0.25 / 1.0 μg/ml of this antibody is required. This biotinylated polyclonal antibody, in conjunction with BioGems Polyclonal Anti-Human MCP-1/MCAF (60-212P) as a capture antibody, allows the detection of at least 0.2 - 0.4 ng/well of recombinant hMCP-1/MCAF.
Direct ELISA:
To detect hMCP-1/MCAF by direct ELISA (using 100 μl/well antibody solution) a concentration of 0.25 / 1.0 μg/ml of this antibody is required. This biotinylated polyclonal antibody, in conjunction with compatible secondary reagents, allows the detection of at least 0.2 - 0.4 ng/well of recombinant hMCP-1/MCAF.
Formulation: A sterile filtered antibody solution was lyophilized from PBS, pH 7.2.
Reconstitution: Centrifuge vial prior to opening. Reconstitute in sterile PBS containing 0.1% BSA to a concentration of 0.1-1.0 mg/ml.
| Is Featured? | No |
|---|
Write Your Own Review