Mouse ACVA (Activin A) ELISA Kit
€0.00
In stock
SKU
ELK5382
Catalog Number: ELK5382
Reactivity: Mouse
Standard Range: 9.38-600 pg/mL
Sensitivity: 5 pg/mL
Information
Request Manual
Questions? Contact us!
Reactivity: Mouse
Standard Range: 9.38-600 pg/mL
Sensitivity: 5 pg/mL
Information
Request Manual
Questions? Contact us!
Test Principle:
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Activin A(ACVA). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Activin A(ACVA). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Activin A(ACVA), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Activin A(ACVA) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Endocrinology, Reproductive science, Hormone metabolism
Alternative Names:
ACV-A, Activin Beta A Beta A Homodimer
Sample Type:
serum, plasma and other biological fluids
Assay Type: Sandwich
Standard: 600 pg/mL
Assay Length: 2h
Assay Length: For Research Use Only
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Activin A(ACVA). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Activin A(ACVA). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Activin A(ACVA), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Activin A(ACVA) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Endocrinology, Reproductive science, Hormone metabolism
Alternative Names:
ACV-A, Activin Beta A Beta A Homodimer
Sample Type:
serum, plasma and other biological fluids
Assay Type: Sandwich
Standard: 600 pg/mL
Assay Length: 2h
Assay Length: For Research Use Only
| Is Featured? | No |
|---|