Rabbit APOA1 (Apolipoprotein A1) ELISA Kit
€0.00
In stock
SKU
ELK2025
Catalog Number: ELK2025
Reactivity: Rabbit
Standard Range: 31.25-2000 ng/mL
Sensitivity: 10.53 ng/mL
Information
Request Manual
Questions? Contact us!
Reactivity: Rabbit
Standard Range: 31.25-2000 ng/mL
Sensitivity: 10.53 ng/mL
Information
Request Manual
Questions? Contact us!
Test Principle:
This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Apolipoprotein A1(APOA1) protein. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Apolipoprotein A1(APOA1). Next,Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Apolipoprotein A1(APOA1) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Metabolic pathway, Cardiovascular biology, Hepatology
Alternative Names:
Apo-A1, ApoA-1 Milano, ProapoA-I, Proapolipoprotein A-I, Truncated apolipoprotein A-I
Sample Type:
serum, plasma and other biological fluids
Assay Type: Competitive Inhibition
Standard: 2000 ng/mL
Assay Length: 2h
Assay Length: For Research Use Only
This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Apolipoprotein A1(APOA1) protein. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Apolipoprotein A1(APOA1). Next,Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Apolipoprotein A1(APOA1) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Metabolic pathway, Cardiovascular biology, Hepatology
Alternative Names:
Apo-A1, ApoA-1 Milano, ProapoA-I, Proapolipoprotein A-I, Truncated apolipoprotein A-I
Sample Type:
serum, plasma and other biological fluids
Assay Type: Competitive Inhibition
Standard: 2000 ng/mL
Assay Length: 2h
Assay Length: For Research Use Only
| Is Featured? | No |
|---|
Write Your Own Review