Rat Ang1-7 (Angiotensin 1-7) ELISA Kit
€0.00
In stock
SKU
ELK7677
Catalog Number: ELK7677
Reactivity: Rat
Standard Range: 3.13-200 pg/mL
Sensitivity: 0.91 pg/mL
Information
Request Manual
Questions? Contact us!
Reactivity: Rat
Standard Range: 3.13-200 pg/mL
Sensitivity: 0.91 pg/mL
Information
Request Manual
Questions? Contact us!
Test Principle:
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Ang1-7(Angiotensin 1-7). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Ang1-7(Angiotensin 1-7). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Ang1-7(Angiotensin 1-7), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Ang1-7(Angiotensin 1-7) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Endocrinology, Cardiovascular biology
Alternative Names:
Ang1-7
Sample Type:
serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluid
Assay Type: Sandwich
Standard: 200 pg/mL
Assay Length: 4.5h
Assay Length: For Research Use Only
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Ang1-7(Angiotensin 1-7). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Ang1-7(Angiotensin 1-7). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Ang1-7(Angiotensin 1-7), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Ang1-7(Angiotensin 1-7) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Endocrinology, Cardiovascular biology
Alternative Names:
Ang1-7
Sample Type:
serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluid
Assay Type: Sandwich
Standard: 200 pg/mL
Assay Length: 4.5h
Assay Length: For Research Use Only
| Is Featured? | No |
|---|
Write Your Own Review