Rat CT1 (Cardiotrophin 1) ELISA Kit
€0.00
In stock
SKU
ELK1568
Catalog Number: ELK1568
Reactivity: Rat
Standard Range: 15.63-1000 pg/mL
Sensitivity: 5.8 pg/mL
Information
Request Manual
Questions? Contact us!
Reactivity: Rat
Standard Range: 15.63-1000 pg/mL
Sensitivity: 5.8 pg/mL
Information
Request Manual
Questions? Contact us!
Test Principle:
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Cardiotrophin 1(CT1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Cardiotrophin 1(CT1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Cardiotrophin 1(CT1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Cardiotrophin 1(CT1) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Cytokine, Tumor immunity, Cardiovascular biology
Alternative Names:
CTF1
Sample Type:
Serum, plasma, tissue homogenates and other biological fluids
Assay Type: Sandwich
Standard: 1000 pg/mL
Assay Length: 4.5h
Assay Length: For Research Use Only
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Cardiotrophin 1(CT1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Cardiotrophin 1(CT1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Cardiotrophin 1(CT1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Cardiotrophin 1(CT1) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Cytokine, Tumor immunity, Cardiovascular biology
Alternative Names:
CTF1
Sample Type:
Serum, plasma, tissue homogenates and other biological fluids
Assay Type: Sandwich
Standard: 1000 pg/mL
Assay Length: 4.5h
Assay Length: For Research Use Only
| Is Featured? | No |
|---|
Write Your Own Review