Rat GCLM (Glutamate Cysteine Ligase, Modifier Subunit) ELISA Kit
€0.00
In stock
SKU
ELK6975
Catalog Number: ELK6975
Reactivity: Rat
Standard Range: 0.16-10 ng/mL
Sensitivity: 0.052 ng/mL
Information
Request Manual
Questions? Contact us!
Reactivity: Rat
Standard Range: 0.16-10 ng/mL
Sensitivity: 0.052 ng/mL
Information
Request Manual
Questions? Contact us!
Test Principle:
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Glutamate Cysteine Ligase, Modifier Subunit(GCLM). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Glutamate Cysteine Ligase, Modifier Subunit(GCLM). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Glutamate Cysteine Ligase, Modifier Subunit(GCLM), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Glutamate Cysteine Ligase, Modifier Subunit(GCLM) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Enzyme & Kinase, Hematology
Alternative Names:
GLCLR, GECS, GCL, Gamma Glutamylcysteine Synthetase, Glutamate Cysteine Ligase Regulatory, Gamma-ECS regulatory subunit, Glutamate cysteine ligase modifier subunit
Sample Type:
Tissue homogenates and other biological fluids.
Assay Type: Sandwich
Standard: 10 ng/mL
Assay Length: 4.5h
Assay Length: For Research Use Only
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Glutamate Cysteine Ligase, Modifier Subunit(GCLM). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Glutamate Cysteine Ligase, Modifier Subunit(GCLM). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Glutamate Cysteine Ligase, Modifier Subunit(GCLM), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Glutamate Cysteine Ligase, Modifier Subunit(GCLM) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Enzyme & Kinase, Hematology
Alternative Names:
GLCLR, GECS, GCL, Gamma Glutamylcysteine Synthetase, Glutamate Cysteine Ligase Regulatory, Gamma-ECS regulatory subunit, Glutamate cysteine ligase modifier subunit
Sample Type:
Tissue homogenates and other biological fluids.
Assay Type: Sandwich
Standard: 10 ng/mL
Assay Length: 4.5h
Assay Length: For Research Use Only
| Is Featured? | No |
|---|
Write Your Own Review