Test Principle:
This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Immunoglobulin M(IgM) protein. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Immunoglobulin M(IgM). Next,Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Immunoglobulin M(IgM) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Infection immunity, Immune molecule, Hematology
Alternative Names:
IGHM, Immunoglobulin Heavy Constant Mu, Ig mu chain C region
Sample Type:
serum, plasma and other biological fluids
Assay Type: Competitive Inhibition
Standard: 20000 ng/mL
Assay Length: 2h
Assay Length: For Research Use Only
This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Immunoglobulin M(IgM) protein. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Immunoglobulin M(IgM). Next,Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Immunoglobulin M(IgM) in the samples is then determined by comparing the OD of the samples to the standard curve.
Research Area: Infection immunity, Immune molecule, Hematology
Alternative Names:
IGHM, Immunoglobulin Heavy Constant Mu, Ig mu chain C region
Sample Type:
serum, plasma and other biological fluids
Assay Type: Competitive Inhibition
Standard: 20000 ng/mL
Assay Length: 2h
Assay Length: For Research Use Only
| Is Featured? | No |
|---|
Write Your Own Review